Article Navigation
Article Contents
-
Case Report
-
Discussion
-
Acknowledgments
-
Abbreviations
-
References
- < Previous
- Next >
Journal Article
, Tze Ping Loh 1Departments of Laboratory Medicine (T.P.L.), Singapore 119074 *Address all correspondence and requests for reprints to: Tze Ping Loh, 5 Lower Kent Ridge Road, Singapore 119074. Search for other works by this author on: Oxford Academic Shih Ling Kao 2Medicine (S.L.K., S.-A.E.S.T., E.S.T., C.M.K.), National University Hospital, Singapore 119074 Search for other works by this author on: Oxford Academic David J. Halsall 3Department of Clinical Biochemistry (D.J.H.), Addenbrooke's Hospital, Cambridge CB2 2QR, United Kingdom Search for other works by this author on: Oxford Academic Sue-Anne Ee Shiow Toh 2Medicine (S.L.K., S.-A.E.S.T., E.S.T., C.M.K.), National University Hospital, Singapore 119074 Search for other works by this author on: Oxford Academic Edmund Chan 4Saw Swee Hock School of Public Health (E.C.), National University of Singapore, Singapore 117597 Search for other works by this author on: Oxford Academic Su Chin Ho 5The Endocrine Clinic (S.C.H.), Mount Elizabeth Medical Centre, Singapore 228510 Search for other works by this author on: Oxford Academic E Shyong Tai 2Medicine (S.L.K., S.-A.E.S.T., E.S.T., C.M.K.), National University Hospital, Singapore 119074 Search for other works by this author on: Oxford Academic Chin Meng Khoo 2Medicine (S.L.K., S.-A.E.S.T., E.S.T., C.M.K.), National University Hospital, Singapore 119074 Search for other works by this author on: Oxford Academic
The Journal of Clinical Endocrinology & Metabolism, Volume 97, Issue 6, 1 June 2012, Pages 1823–1828, https://doi.org/10.1210/jc.2011-3490
Published:
01 June 2012
Article history
Received:
29 December 2011
Accepted:
05 March 2012
Published:
01 June 2012
- Split View
- Views
- Article contents
- Figures & tables
- Video
- Audio
- Supplementary Data
-
Cite
Cite
Tze Ping Loh, Shih Ling Kao, David J. Halsall, Sue-Anne Ee Shiow Toh, Edmund Chan, Su Chin Ho, E Shyong Tai, Chin Meng Khoo, Macro-Thyrotropin: A Case Report and Review of Literature, The Journal of Clinical Endocrinology & Metabolism, Volume 97, Issue 6, 1 June 2012, Pages 1823–1828, https://doi.org/10.1210/jc.2011-3490
Close
Search
Close
Search
Advanced Search
Search Menu
Context:
Isolated elevation of TSH in the absence of thyroid symptoms can be very rarely caused by a macromolecule formed between TSH and Ig (macro-TSH), confounding the interpretation of thyroid function test results.
Objective:
We described the use of several commonly available laboratory-based approaches to investigate an isolated TSH elevation [232 mIU/liter; free T4, 10 pmol/liter (reference interval, 10.0–23.0 pmol/liter), Vitros platform] in a clinically euthyroid elderly gentleman, which led to the diagnosis of macro-TSH.
Methods and Results:
TSH concentration of the patient was significantly lower (122 mIU/liter) when measured on the Advia Centaur platform. Serial dilution of the patient's sample showed a nonlinear increase in TSH recovery at increasing dilution (nonlinearity). Polyethylene glycol precipitation and mixing the patient's sample with a hypothyroid patient sample showed reduced TSH recovery, suggesting the presence of a high molecular weight interfering substance and excess TSH binding capacity, respectively. Heterophile blocking tube studies and rheumatoid factors were negative. Gel filtration chromatography demonstrated a TSH peak fraction that approximated the molecular size of IgG; together with the excess TSH binding capacity, this indicated the presence of TSH-IgG macro-TSH. A review of 12 macro-TSH case reports showed that samples with macro-TSH produce over-recovery with dilution, return negative results on anti-animal and anti-heterophile blocking studies, and commonly have recovery of less than 20% when subjected to polyethylene glycol precipitation.
Conclusion:
Macro-TSH is an underrecognized laboratory interference. Routine laboratory techniques described above can help diagnose this rare entity. A close dialogue between the physician and the laboratory is important in approaching such cases.
An elevated TSH concentration in the presence of normal free T4 (fT4) concentration is most commonly encountered in the setting of subclinical hypothyroidism. Other less common causes include TSH resistance syndromes, biologically inactive TSH, and laboratory interferences (1). The interpretation of such biochemical results can present as clinical conundrums, especially when the clinical symptoms are subtle or absent.
Macro-TSH is a rare laboratory interference that can interfere with laboratory measurement of TSH, leading to spuriously high results (1). It is a macromolecule that is formed between autoimmune anti-TSH Ig and TSH molecule. The diagnosis of macro-TSH is confirmed by gel filtration chromatography, which can be used to identify an Ig-TSH complex by dissociation or recovery studies. However, this is expensive and not routinely available in most clinical laboratories. Here, we describe the use of several commonly available laboratory techniques to investigate a case of isolated TSH elevation in a clinically euthyroid patient that led to the diagnosis of macro-TSH. An algorithm to guide the laboratory investigation of cases suspected of laboratory interference, including macro-TSH, is proposed.
Case Report
A 60-yr-old gentleman was admitted to the hospital for a left intertrochanteric fracture after an episode of syncope. His past medical history included hypertension, ischemic heart disease, and dyslipidemia. His oral medications were aspirin, atenolol, enalapril, lovastatin, and sublingual glyceryl trinitrate. During admission, he was noted to have sinus bradycardia (55–60 beats per minute). Although the bradycardia could have been attributed to the atenolol treatment, thyroid function tests were performed to exclude hypothyroidism. The thyroid function tests showed a markedly elevated TSH (232 mIU/liter; reference interval, 0.45–5.0 mIU/liter) with a low-normal fT4 (10 pmol/liter; reference interval, 10.0–23.0 pmol/liter). The thyroid function test was performed on the Vitros 5600 platform (Ortho Clinical Diagnostics, Rochester, NY).
Further history from this patient revealed no symptoms of hypothyroidism. There was no personal or family history of thyroid or autoimmune disorders. On physical examination, apart from sinus bradycardia, he was clinically euthyroid. There was no thyromegaly. The antithyroid peroxidase antibodies were raised at 496 IU/ml (reference interval, 0–50 IU/ml). Antithyroglobulin and anti-TSH receptor antibodies were not elevated. The lipid profile and SHBG concentration were within reference limits.
The suspicion of a spuriously elevated TSH was raised because the patient was clinically euthyroid despite the markedly elevated TSH concentration. To screen for the presence of laboratory interference that may cause the markedly elevated TSH, TSH measurement was repeated on the same patient sample using another analytical platform (Advia Centaur; Siemens Healthcare Diagnostics, Deerfield, IL). An interfering substance (e.g. heterophile antibodies) may react variably to the different antibodies employed by different immunoassays, giving rise to grossly discrepant results between different assays. The TSH concentration measured by the Advia Centaur analyzer remained elevated (122 mIU/liter), although significantly lower than the results of the Vitros platform. The large difference could not be accounted for by the analytical bias between the assays alone, suggesting a high likelihood of assay interference. The fT4 concentration remained within the reference limits on the Advia Centaur platform. All subsequent TSH measurements were performed on the Advia Centaur platform.
In the linearity study, the serum of the patient was diluted with the TSH assay diluent provided by the manufacturer at 1:2 to 1:10 dilutions. The TSH recovery of the diluted samples showed increasing concentration (increasing recovery) at increasing dilution factor, showing nonlinearity. Ten times dilution of the patient's serum yielded a recovery of 135% (neat, 122 mIU/liter; 10× dilution, 165 mIU/liter). Nonlinearity can be caused by heterophile antibodies, rheumatoid factor, and macro-TSH. Rheumatoid factor, which can behave like heterophile antibodies, was undetectable in this patient.
The serum of the patient was then subjected to polyethylene glycol (PEG) precipitation (2) to remove high molecular weight proteins, including interfering antibodies and macro-TSH. The post-PEG TSH recovery for this patient was 3.2% (pre-PEG, 122 mIU/liter; post-PEG, 3.9 mIU/liter), indicating the presence of a high molecular weight interfering substance. When a euthyroid patient serum was subjected to the same PEG treatment in the same run, the recovery was 40% (pre-PEG, 2.42 mIU/liter; post-PEG, 0.96 mIU/liter). Incubation of the patient's serum with heterophile blocking tube (Scantibodies, Santee, CA) returned 95% recovery and was considered a negative study. However, heterophile blocking tube is a specific but insensitive test for heterophile antibodies interference.
From the results obtained up to this point, heterophile antibodies and macro-TSH remained possible causes of the interference. Patients with macro-TSH can contain excess free anti-TSH antibody that can sequester TSH and lower the TSH measurement. To examine this, the sample of the patient (122 mIU/liter, Advia Centaur; 217 mIU/liter, Vitros) was incubated with a sample from a patient known to have hypothyroidism (165 mIU/liter, Advia Centaur; 142 mIU/liter, Vitros) at 1:1 ratio for 4 h. The recovery of TSH after the incubation was 85% (expected concentration, 144 mIU/liter; measured concentration, 123 mIU/liter) when measured using the Advia Centaur platform and 97% (expected concentration, 180 mIU/liter; measured concentration, 174 mIU/liter) on the Vitros analyzer. The reduced TSH recovery after the incubation suggested the presence of excess TSH binding capacity, which occurs in macro-TSH but not in heterophile antibody interference.
The biological activity of the TSH molecule of the patient was assessed by thyroid stimulating Ig bioassay, as previously described (3). Briefly, the sample of the patient was treated with PEG. The precipitate was then incubated with the cell line of the bioassay, and the cAMP generated was measured. The bioactivity of the sample of the patient was 120% compared with pooled serum control (reference interval, 50–179%), suggesting that the presence of biologically active interfering substance was unlikely. The result of this experiment was consistent with the euthyroid state and the absence of thyromegaly on clinical examination.
Collectively, the results suggested the presence of a high molecular weight interfering substance. This substance has excess capacity to sequester TSH and low biological activity (Table 1). Assay interference by heterophile antibodies or rheumatoid factors were less likely based on the above investigations. The presence of a high molecular mass TSH immunoreactivity was confirmed using gel filtration chromatography as previously described (4). The TSH concentrations were measured by the Perkin-Elmer DELFIA assay, which was employed by the reference laboratory performing the gel filtration chromatography. A TSH peak fraction that approximated the molecular size of IgG was found, suggesting the presence of macro-TSH or a cross-linking heterophile (Fig. 1). When the serum of the patient was incubated with a sample from a patient with hypothyroidism and reanalyzed, the immunoreactivity of the high molecular weight species increased, confirming the presence of excess TSH binding capacity in the patient serum and the presence of macro-TSH.
Table 1.
Summary of the results of the procedures to identify the false-positive TSH result due to macro-TSH
Procedures on patient's serum | TSH results | Conclusion |
---|---|---|
Untreated | ||
Advia Centaur | 122 mIU/liter | Inappropriately elevated TSH levels despite clinical euthyroidism, suggestive of assay interference |
Vitros | 232 mIU/liter | |
Dilutions in Advia Centaur diluent, 10-fold | 165 mIU/liter; 135% recovery | Increasing recoveries for patient sample suggest interference from heterophile antibodies, rheumatoid factor, or macro-TSH |
Precipitation with PEG and reassay supernatant | 3.9 mIU/liter; 3.2% recovery | Presence of a high molecular weight interfering substance |
Heterophile-blocking tube | 116 mIU/liter; 95% recovery | Considered a negative study, although heterophile antibodies interference cannot be ruled out because this test is specific but nonsensitive for heterophile antibodies interference |
Incubation with hypothyroid patient sample | Expected, 144 mIU/liter; measured, 123 mIU/liter; 85% recovery | Presence of excess TSH binding capacity, likely macro-TSH interference |
Gel filtration chromatography analysis (Perkin-Elmer DELFIA assay) | Presence of high molecular weight TSH fraction, which increased after incubation with hypothyroid patient sample | Confirmed the presence of macro-TSH |
Procedures on patient's serum | TSH results | Conclusion |
---|---|---|
Untreated | ||
Advia Centaur | 122 mIU/liter | Inappropriately elevated TSH levels despite clinical euthyroidism, suggestive of assay interference |
Vitros | 232 mIU/liter | |
Dilutions in Advia Centaur diluent, 10-fold | 165 mIU/liter; 135% recovery | Increasing recoveries for patient sample suggest interference from heterophile antibodies, rheumatoid factor, or macro-TSH |
Precipitation with PEG and reassay supernatant | 3.9 mIU/liter; 3.2% recovery | Presence of a high molecular weight interfering substance |
Heterophile-blocking tube | 116 mIU/liter; 95% recovery | Considered a negative study, although heterophile antibodies interference cannot be ruled out because this test is specific but nonsensitive for heterophile antibodies interference |
Incubation with hypothyroid patient sample | Expected, 144 mIU/liter; measured, 123 mIU/liter; 85% recovery | Presence of excess TSH binding capacity, likely macro-TSH interference |
Gel filtration chromatography analysis (Perkin-Elmer DELFIA assay) | Presence of high molecular weight TSH fraction, which increased after incubation with hypothyroid patient sample | Confirmed the presence of macro-TSH |
TSH concentrations were reassayed using Advia Centaur assay for all the procedures, except for gel filtration chromatography analysis.
Open in new tab
Table 1.
Summary of the results of the procedures to identify the false-positive TSH result due to macro-TSH
Procedures on patient's serum | TSH results | Conclusion |
---|---|---|
Untreated | ||
Advia Centaur | 122 mIU/liter | Inappropriately elevated TSH levels despite clinical euthyroidism, suggestive of assay interference |
Vitros | 232 mIU/liter | |
Dilutions in Advia Centaur diluent, 10-fold | 165 mIU/liter; 135% recovery | Increasing recoveries for patient sample suggest interference from heterophile antibodies, rheumatoid factor, or macro-TSH |
Precipitation with PEG and reassay supernatant | 3.9 mIU/liter; 3.2% recovery | Presence of a high molecular weight interfering substance |
Heterophile-blocking tube | 116 mIU/liter; 95% recovery | Considered a negative study, although heterophile antibodies interference cannot be ruled out because this test is specific but nonsensitive for heterophile antibodies interference |
Incubation with hypothyroid patient sample | Expected, 144 mIU/liter; measured, 123 mIU/liter; 85% recovery | Presence of excess TSH binding capacity, likely macro-TSH interference |
Gel filtration chromatography analysis (Perkin-Elmer DELFIA assay) | Presence of high molecular weight TSH fraction, which increased after incubation with hypothyroid patient sample | Confirmed the presence of macro-TSH |
Procedures on patient's serum | TSH results | Conclusion |
---|---|---|
Untreated | ||
Advia Centaur | 122 mIU/liter | Inappropriately elevated TSH levels despite clinical euthyroidism, suggestive of assay interference |
Vitros | 232 mIU/liter | |
Dilutions in Advia Centaur diluent, 10-fold | 165 mIU/liter; 135% recovery | Increasing recoveries for patient sample suggest interference from heterophile antibodies, rheumatoid factor, or macro-TSH |
Precipitation with PEG and reassay supernatant | 3.9 mIU/liter; 3.2% recovery | Presence of a high molecular weight interfering substance |
Heterophile-blocking tube | 116 mIU/liter; 95% recovery | Considered a negative study, although heterophile antibodies interference cannot be ruled out because this test is specific but nonsensitive for heterophile antibodies interference |
Incubation with hypothyroid patient sample | Expected, 144 mIU/liter; measured, 123 mIU/liter; 85% recovery | Presence of excess TSH binding capacity, likely macro-TSH interference |
Gel filtration chromatography analysis (Perkin-Elmer DELFIA assay) | Presence of high molecular weight TSH fraction, which increased after incubation with hypothyroid patient sample | Confirmed the presence of macro-TSH |
TSH concentrations were reassayed using Advia Centaur assay for all the procedures, except for gel filtration chromatography analysis.
Open in new tab
Fig. 1.
Open in new tabDownload slide
Gel-filtration chromatogram of the patient sample showing a TSH peak fraction that approximated the molecular size of IgG (solid dots). The high molecular weight TSH peak fraction became higher (solid triangles) after mixing with a hypothyroid TSH sample, showing excess TSH binding capacity in the patient sample. The low molecular weight TSH fraction (near the albumin fraction) increased as a result of the excess TSH from the hypothyroid sample that is not bound by the excess TSH binding capacity of the patient.
Discussion
Assay interference in the measurement of TSH is relatively common. Analytically suspicious TSH results have been reported to be present in 0.5–5% of patient samples (5, 6), and up to 38.2 and 55.6% when samples of healthy subjects were screened for interference by a stringent serial dilution protocol and heterophile-blocking tube tests, respectively (7). As such, spurious elevation of TSH should be considered and investigated when isolated elevations of TSH are incongruent with the patient's clinical presentation, particularly when these elevations are extreme.
Substances that commonly interfere with TSH assays include heterophile antibodies, human antimouse/animal antibodies, and rheumatoid factors (8). Monoclonal Ig has also been shown to positively (9) and negatively (10) interfere with TSH assays. With the advent of the use of therapeutic immunological agents, spuriously high TSH results arising from monoclonal mouse antibody and anti-idiotypic antibody are also recognized (11, 12). A common mechanism for positive assay interference is the cross-linking of capture and signal antibodies of sandwich immunoassay, thereby falsely generating assay signal and spuriously elevating the TSH result. Interference from antibodies has been reviewed in detail elsewhere (13, 14). Highly discrepant TSH measurements on different TSH assays and the finding of nonlinearity on serial dilution provide early indication of the presence of assay interference.
Circulating autoimmune antithyroid hormone antibodies that affect thyroid hormone assays have been documented (15, 16). Similarly, circulating autoimmune anti-TSH antibody that interferes with TSH measurement has been reported in patients receiving bovine TSH as well as those with autoimmune thyroid diseases (17). Macro-TSH molecule is a rare entity and has only been demonstrated more recently. TSH is a small molecule that is excreted via the kidneys. When TSH forms a macromolecule complex with an antibody, the renal clearance of TSH is markedly reduced. However, the immunoreactivity of the TSH complex may be retained. The accumulated macro-TSH is therefore reflected as spuriously elevated TSH concentrations. Crucially, macro-TSH can occur in patients with TSH concentration that is within reference limits (18). However, the biological activity of macro-TSH may be reduced, and the patient remains clinically euthyroid.
A MEDLINE search revealed 12 cases of laboratory-confirmed macro-TSH from recently published case reports (2, 3, 18–22). Among these patients, the majority were females and displayed no symptoms of thyroid disorders, except one with clinical features of hyperthyroidism (19). Some of these patients had elevated concentrations of antithyroglobulin antibodies (2) and anti-TSH receptor antibodies (18). In contrast, our patient had an elevated concentration of antithyroid peroxidase antibodies, which was not previously reported. In all the cases but one (21), macro-TSH is formed between anti-TSH IgG and TSH molecule.
Vertical transfer of anti-TSH antibody from mother to fetus has been described in two reports. In these reports, the neonates presented with hyperthyrotropinemia on routine neonatal screening (3, 20). Misdiagnosis of this benign assay interference can have detrimental consequences to the newborn. Elevated TSH results in a euthyroid newborn should be investigated initially by measuring the TSH and the fT4 of the mother (23). If the maternal TSH is elevated in isolation, macro-TSH should be considered and investigated appropriately. If macro-TSH is present, the TSH concentration of the newborn should fall gradually and normalize by 8 months, mirroring the natural elimination of maternal antibodies in a newborn (20).
From the case reports, all macro-TSH patients' samples produced over-recovery when they were diluted above a factor of five. Treating the samples with anti-animal and anti-heterophile blocking reagents always produced negative results. With PEG precipitation, the TSH recoveries were less than 20%, except for two cases where the recoveries were about 50% (19, 21). In comparison, 10 presumably normal samples produced TSH recovery of 58–79% after treatment with PEG precipitation (19). However, it is important to note that these values are assay dependent, and individual laboratories should derive local reference values for PEG-treated TSH measurement.
Macro-TSH appears to affect most commercially available TSH assays. It is less detectable compared with native TSH because the presence of the attached Ig on the TSH molecule may compromise the antigen-antibody binding of the TSH assays. Furthermore, the affinity of the antibodies used in the assays influences their ability to detect macro-TSH. The Roche and Perkin-Elmer DELFIA assays are more sensitive to macro-TSH interference (reporting higher spuriously elevated TSH results) (19–22), whereas the Advia Centaur assay is least sensitive to such interference (reporting lower spuriously elevated TSH results) (2, 4, 21, 22).
When a macro-TSH sample is mixed and incubated with an interference-free hypothyroid sample, the excess anti-TSH antibody from the macro-TSH sample will bind to the excess native TSH of the hypothyroid sample, forming macro-TSH. The TSH recovery of the mixture is reduced because some of the native TSH has been converted to the less detectable macro-TSH. However, the reduction of TSH recovery occurs to a lesser extent in TSH assays that are sensitive to macro-TSH because these assays can still detect considerable amounts of the newly formed macro-TSH. Hence, assays that are less sensitive to macro-TSH are better suited for this investigation because the magnitude of fall in TSH recovery will be more noticeable.
Macro-TSH is suggested when a macro-TSH/hypothyroid mixture returns lower TSH measurement after the incubation, and the TSH result of the mixture is lower in assays known to be less sensitive to macro-TSH. However, these methods are not sensitive for the diagnosis of macro-TSH interference because it is possible that a high-affinity, low-concentration anti-TSH antibody may not present with excess serum TSH binding capacity. These methods are in routine use in the laboratory of one of the authors (D.J.H.). From his personal experience, a recovery of less than 20% is usually associated with macro-TSH, confirmed on subsequent gel filtration chromatography analysis.
A definitive test for macro-TSH is the dissociation experiment by gel filtration chromatography. This technique involves using an acidic elution buffer (pH 3.0) to dissociate the antigen-antibody complex during gel filtration chromatography (2). Under such conditions, the peak fraction of the high molecular weight (Ig-associated) TSH species would diminish, whereas the peak fraction of the low molecular weight (monomer) TSH species would increase. This finding was not observed in our patient because the acidic nature of the eluent has interfered with the immunoassay (i.e. Perkin-Elmer DELFIA assay) used to measure the TSH concentration.
The clinical significance and prevalence of macro-TSH is currently not clear. Nevertheless, early recognition of this assay interference can avoid misdiagnosis and unnecessary investigation and/or treatment. Patients with macro-TSH should probably be followed up, especially those with elevated antithyroid antibodies and newborns (23). Because TSH measurements are no longer reliable in this clinical scenario, these patients should be monitored clinically and with fT4 measurements. In this situation, fT4 should be measured by equilibrium dialysis or ultrafiltration followed by HPLC-tandem mass spectrometry. These methods have better inverse log-linear correlation coefficient between TSH and fT4 than the direct analog immunoassays (24–26).
In conclusion, this report highlights the importance of close dialogue between the physician and the laboratory in approaching such cases. Macro-TSH can be strongly suspected when a sample shows under-recovery after being subjected to PEG precipitation and incubation with normal hypothyroid sample and over-recovery on serial dilution. Anti-animal and anti-heterophile antibodies should be absent. When these criteria are met, the diagnosis of macro-TSH can be confirmed by gel filtration chromatography. A diagnostic strategy for macro-TSH is proposed in Fig. 2.
Fig. 2.
Open in new tabDownload slide
A proposed diagnostic strategy for the investigation of macro-TSH.
Acknowledgments
We are indebted to Dr. Lee Lee Wong for her technical help.
This report was partly supported by the Department of Medicine Fund, National University Hospital, Singapore.
Disclosure Summary: None of the authors has any conflict of interest to declare.
Abbreviations
References
1.
Gurnell M Halsall DJ Chatterjee VK
2011
What should be done when thyroid function tests do not make sense?
Clin Endocrinol (Oxf)
74
:
673
–
678
2.
Sakai H f*ckuda G
Suzuki
N
,Watanabe
C
,Odawara
M
2009
Falsely elevated thyroid-stimulating hormone (TSH) level due to macro-TSH.
Endocr J
56
:
435
–
440
3.
Khoo DH Ho SC Seah LL Fong KS Tai ES Chee SP Eng PH Aw SE Fok AC
1999
The combination of absent thyroid peroxidase antibodies and high thyroid-stimulating immunoglobulin levels in Graves' disease identifies a group at markedly increased risk of ophthalmopathy.
Thyroid
9
:
1175
–
1180
4.
Halsall DJ Fahie-Wilson MN Hall SK Barker P Anderson J Gama R Chatterjee VK
2006
Macro thyrotropin-IgG complex causes factitious increases in thyroid-stimulating hormone screening tests in a neonate and mother.
Clin Chem
52
:
1968
–
1969
;
author reply 1969–1970
5.
Ismail AA Walker PL Barth JH Lewandowski KC Jones R Burr WA
2002
Wrong biochemistry results: two case reports and observational study in 5310 patients on potentially misleading thyroid-stimulating hormone and gonadotropin immunoassay results.
Clin Chem
48
:
2023
–
2029
6.
Marks V
2002
False-positive immunoassay results: a multicenter survey of erroneous immunoassay results from assays of 74 analytes in 10 donors from 66 laboratories in seven countries.
Clin Chem
48
:
2008
–
2016
7.
Emerson JF Ngo G Emerson SS
2003
Screening for interference in immunoassays.
Clin Chem
49
:
1163
–
1169
8.
Tate J Ward G
2004
Interferences in immunoassay.
Clin Biochem Rev
25
:
105
–
120
9.
Imperiali M Jelmini P Ferraro B Keller F della Bruna R Balerna M Giovanella L
2010
Interference in thyroid-stimulating hormone determination.
Eur J Clin Invest
40
:
756
–
758
10.
Luzzi VI Scott MG Gronowski AM
2003
Negative thyrotropin assay interference associated with an IgGκ paraprotein.
Clin Chem
49
:
709
–
710
11.
Choi WW Srivatsa S Ritchie JC
2005
Aberrant thyroid testing results in a clinically euthyroid patient who had received a tumor vaccine.
Clin Chem
51
:
673
–
675
12.
Seghers J Schrurs F De Nayer P Beckers C
1989
Interference in thyrotropin (TSH) determination: falsely elevated TSH values in a transplanted patient.
Eur J Nucl Med
15
:
194
–
196
13.
Després N Grant AM
1998
Antibody interference in thyroid assays: a potential for clinical misinformation.
Clin Chem
44
:
440
–
454
14.
Ismail AA
2009
Interference from endogenous antibodies in automated immunoassays: what laboratorians need to know.
J Clin Pathol
62
:
673
–
678
15.
Premachandra BN Blumenthal HT
1967
Abnormal binding of thyroid hormone in sera from patients with Hashimoto's disease.
J Clin Endocrinol Metab
27
:
931
–
936
16.
Sakata S Matsuda M Ogawa T Takuno H Matsui I Sarui H Yasuda K
1994
Prevalence of thyroid hormone autoantibodies in healthy subjects.
Clin Endocrinol (Oxf)
41
:
365
–
370
17.
Sapin R d'Herbomez M Schlienger JL Wemeau JL
1998
Anti-thyrotropin antibody interference in thyrotropin assays.
Clin Chem
44
:
2557
–
2559
18.
Lewis EJ Lim R Joseph F Ewins D Goenka N Bowles SA Faye SA Kertesz G
2011
Recognising macro-TSH: a rare cause of inappropriately high TSH values.
Clin Chem Lab Med
49
(
Supp
):
S421
OpenURL Placeholder Text
19.
Verhoye E Van den Bruel A Delanghe JR Debruyne E Langlois MR
2009
Spuriously high thyrotropin values due to anti-thyrotropin antibodies in adult patients.
Clin Chem Lab Med
47
:
604
–
606
20.
Rix M Laurberg P Porzig C Kristensen SR
2011
Elevated thyroid-stimulating hormone level in a euthyroid neonate caused by macro thyrotropin-IgG complex.
Acta Paediatr
100
:
e135
–
e137
21.
Vieira JG Maciel RM Hauache OM Nishida SK Boelter DM Pinheiro MF
2006
Unexpected high values of TSH: the presence of high molecular weight forms (macro TSH) must be investigated.
Arq Bras Endocrinol Metabol
50
:
445
–
449
22.
Mendoza H Connacher A Srivastava R
2009
Unexplained high thyroid stimulating hormone: a “BIG” problem
.
BMJ Case Rep
pii:bcr01.2009.1474
OpenURL Placeholder Text
23.
Newman JD Bergman PB Doery JCG
2006
Macro thyrotropin-IgG complex causes factitious increases in thyroid-stimulating hormone screening tests in a neonate and mother (comments).
Clin Chem
52
:
1969
–
1970
24.
van Deventer HE Mendu DR Remaley AT Soldin SJ
2011
Inverse log-linear relationship between thyroid-stimulating hormone and free thyroxine measured by direct analog immunoassay and tandem mass spectrometry.
Clin Chem
57
:
122
–
127
25.
Soldin OP Soldin SJ
2011
Thyroid hormone testing by tandem mass spectrometry.
Clin Biochem
44
:
89
–
94
26.
Jonklaas J Kahric-Janicic N Soldin OP Soldin SJ
2009
Correlations of free thyroid hormones measured by tandem mass spectrometry and immunoassay with thyroid-stimulating hormone across 4 patient populations.
Clin Chem
55
:
1380
–
1388
Copyright © 2012 by The Endocrine Society
Download all slides
Advertisem*nt
Citations
Views
8,036
Altmetric
More metrics information
Metrics
Total Views 8,036
6,032 Pageviews
2,004 PDF Downloads
Since 1/1/2017
Month: | Total Views: |
---|---|
January 2017 | 2 |
February 2017 | 14 |
March 2017 | 11 |
April 2017 | 10 |
May 2017 | 19 |
June 2017 | 18 |
July 2017 | 28 |
August 2017 | 22 |
September 2017 | 13 |
October 2017 | 16 |
November 2017 | 24 |
December 2017 | 71 |
January 2018 | 111 |
February 2018 | 85 |
March 2018 | 76 |
April 2018 | 61 |
May 2018 | 101 |
June 2018 | 67 |
July 2018 | 60 |
August 2018 | 82 |
September 2018 | 57 |
October 2018 | 87 |
November 2018 | 100 |
December 2018 | 48 |
January 2019 | 42 |
February 2019 | 85 |
March 2019 | 71 |
April 2019 | 92 |
May 2019 | 99 |
June 2019 | 115 |
July 2019 | 105 |
August 2019 | 102 |
September 2019 | 118 |
October 2019 | 120 |
November 2019 | 99 |
December 2019 | 78 |
January 2020 | 81 |
February 2020 | 106 |
March 2020 | 104 |
April 2020 | 60 |
May 2020 | 42 |
June 2020 | 73 |
July 2020 | 84 |
August 2020 | 106 |
September 2020 | 89 |
October 2020 | 60 |
November 2020 | 87 |
December 2020 | 87 |
January 2021 | 111 |
February 2021 | 146 |
March 2021 | 127 |
April 2021 | 96 |
May 2021 | 112 |
June 2021 | 134 |
July 2021 | 127 |
August 2021 | 98 |
September 2021 | 136 |
October 2021 | 147 |
November 2021 | 115 |
December 2021 | 84 |
January 2022 | 100 |
February 2022 | 77 |
March 2022 | 109 |
April 2022 | 111 |
May 2022 | 137 |
June 2022 | 96 |
July 2022 | 98 |
August 2022 | 90 |
September 2022 | 97 |
October 2022 | 132 |
November 2022 | 118 |
December 2022 | 132 |
January 2023 | 183 |
February 2023 | 109 |
March 2023 | 134 |
April 2023 | 120 |
May 2023 | 129 |
June 2023 | 93 |
July 2023 | 128 |
August 2023 | 88 |
September 2023 | 123 |
October 2023 | 128 |
November 2023 | 118 |
December 2023 | 101 |
January 2024 | 143 |
February 2024 | 76 |
March 2024 | 128 |
April 2024 | 135 |
May 2024 | 82 |
Email alerts
Article activity alert
Advance article alerts
New issue alert
Receive exclusive offers and updates from Oxford Academic
The Natural History of Subclinical Hypothyroidism in the Elderly: The Cardiovascular Health Study
Age and the Thyrotropin Response to Hypothyroxinemia
Thyrotropin and Thyroid Antibodies as Predictors of Hypothyroidism: A 13-Year, Longitudinal Study of a Community-Based Cohort Using Current Immunoassay Techniques
Universal Screening Versus Case Finding for Detection and Treatment of Thyroid Hormonal Dysfunction During Pregnancy
Related articles in PubMed
Citing articles via
Google Scholar
-
Latest
-
Most Read
-
Most Cited
More from Oxford Academic
Clinical Medicine
Endocrinology and Diabetes
Medicine and Health
Books
Journals
Advertisem*nt